0903601149
PRODUCT LIST
Online Support
Support 1
Support 2
Support 3
Support 4
0903601149
028-39770018 thaiasianstar@yahoo.com
Access Statistics
Online: 25
Total hits: 1554624
Facebook
Chi tiết sản phẩm
Industrial Multimeters: Fluke 87V Ex Intrinsically Safe True RMS Multimeter
Mã Số: 
Giá Bán: Contacts us

 

Industrial Multimeters: Fluke 87V Ex Intrinsically Safe True RMS Multimeter


Provider: Fluke
Category: Fluke-Test tools / Digital Multimeters
Price: Call us (84-8) 39 572 812
 

 

87V Ex 

The 87V Ex Features:

 

  • ATEX safety rating for use in Ex-zone 1 and zone 2
  • CAT IV 600 V electrical safety rating
  • Unique function for accurate voltage and frequency measurements on variable speed motor drives (VSD’s)
  • Large display with bright, two-level backlight makes the 87V Ex easy to read in all lighting environments
  • Built-in thermometer (probe included)
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • 4-1/2 digit mode for precise measurements (20,000 counts)
  • Measure up to 1000 V and 10 A (ac/dc)
  • Frequency to 200 kHz and % duty cycle
  • Resistance, continuity and diode test
  • 10,000 μF capacitance range for components and motor caps
  • Min/Max-Average and Peak capture to record transients and variations automatically
  • Relative mode to remove test lead interference on resistance measurements
  • Auto and manual ranging for maximum flexibility
  • Analog bargraph for fast changing or unstable signals
  • Input Alert provides

Safety ratings

  • ATEX safety rating: II 2 G EEx ia IIC T4
  • Electrical safety rating: EN61010-1 CAT IV 600 V and CAT III, 1000 V
General Specifications
Voltage DC
Maximum voltage:  1000 V
Accuracy:  ± (0.05 % + 1)
Maximum resolution:  10 μV
Voltage AC
Maximum voltage:  1000 V
Accuracy:  ± (0.7 % + 2) True-rms
AC bandwidth:  20 kHz
Maximum resolution:  10 μV
Current DC
Maximum amps:  10 A (20 A for 30 seconds maximum)
Amps accuracy:  ± (0.2 % + 2)
Maximum resolution:  0.01 μA
Current AC
Maximum amps:  10 A (20 A for 30 seconds maximum)
Amps accuracy:  ± (1.0 % + 2)
Maximum resolution:  True-rms 0.01 μA
Resistance
Maximum resistance:  50 MΩ
Accuracy:  ± (0.2 % + 1)
Maximum resolution:  0.01 Ω
Capacitance
Maximum capacitance:  9,999 μF
Accuracy:  ± (1 % + 2)
Maximum resolution:  0.001 nF
Frequency
Maximum frequency:  200 kHz
Accuracy:  ± (0.005 % + 1)
Maximum resolution:  0.001 Hz
Duty Cycle
Maximum duty cycle:  99.90 %
Accuracy:  ± (0.2 % per khz +0.1 %)
Maximum resolution:  0.10 %
Temperature
Range:  -200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe
80BK Temperature Probe
Range:  -40.0 °C to 260 °C (-40 °F to 500 °F)
Accuracy:  2.2 °C or 2 % whichever is greater
Conductance
Maximum conductance:  60.00 nS
Accuracy:  ± (1.0 % + 10)
Maximum resolution:  0.001 nS
Diode
Range:  3 V
Resolution:  1 mV
Accuracy:  ± (2 % + 1)
Duty Cycle Range
Accuracy:  Within ± (0.2 % per kHz + 0.1 %)
Measurements restriction in Ex-hazardous area
Voltage:  65 V
Current:  5 A

 

Environmental Specifications
Operating Temperature
   -20 °C to +50 °C
Storage Temperature
   -40 °C to +60 °C
Humidity (Without Condensation)
   0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C)
Operating Altitude
   2000 m

 

Safety Specifications
Overvoltage category
   EN 61010-1 to 1000 V CAT III, 600 V CAT IV
Agency Approvals
   CSA, TÜV
ATEX certification
   Ex II 2 G EEx ia IIC T4
Agency Approvals
   ZELM 05 ATEX 0274

 

Mechanical & General Specifications
Size
   201 x 98 x 52 mm (with holster)
Weight
   12,5 oz. (355 kg) with holster
Display (Digital)
   6000 counts updates 4/sec. 19,999 counts in high-resolution mod
Display (Analog)
   32 segments, updates 40/sec.
Warranty
   1 year
Battery Life
   ~400 hours typical without backlight
Shock
   1 Meter drop per IEC 61010-1:2001
Vibration
   Per MIL-PRF-28800 for a Class 2 instrument

 

Intrinsically safe version of the world’s most popular Multimeter

With its high performance, accuracy and motor drive compatibility, the Fluke 87V is the most popular industrial multimeter in the world. Now Fluke has introduced a new intrinsically safe version – the 87V Ex – for measurements in and around hazardous areas.

The new Fluke 87V Ex has all the measurement and troubleshooting functions of the proven Fluke 87V. Unlike most other ATEX-certified tools, it can be used both inside and outside the hazardous zone (ATEX Zones 1 & 2) without compromising performance or compliance. So there’s no need to carry different tools for use inside or outside the hazardous zones. It also has a built-in thermometer with TC probe, further reducing technicians’ tool counts.

Xem thêm: Giá Que Hàn nhôm