The 87V Ex Features:
- ATEX safety rating for use in Ex-zone 1 and zone 2
- CAT IV 600 V electrical safety rating
- Unique function for accurate voltage and frequency measurements on variable speed motor drives (VSD’s)
- Large display with bright, two-level backlight makes the 87V Ex easy to read in all lighting environments
- Built-in thermometer (probe included)
- True-rms ac voltage and current for accurate measurements on non-linear signals
- 4-1/2 digit mode for precise measurements (20,000 counts)
- Measure up to 1000 V and 10 A (ac/dc)
- Frequency to 200 kHz and % duty cycle
- Resistance, continuity and diode test
- 10,000 μF capacitance range for components and motor caps
- Min/Max-Average and Peak capture to record transients and variations automatically
- Relative mode to remove test lead interference on resistance measurements
- Auto and manual ranging for maximum flexibility
- Analog bargraph for fast changing or unstable signals
- Input Alert provides
|
Safety ratings
- ATEX safety rating: II 2 G EEx ia IIC T4
- Electrical safety rating: EN61010-1 CAT IV 600 V and CAT III, 1000 V
|
General Specifications |
Voltage DC |
Maximum voltage: |
1000 V |
Accuracy: |
± (0.05 % + 1) |
Maximum resolution: |
10 μV |
|
Voltage AC |
Maximum voltage: |
1000 V |
Accuracy: |
± (0.7 % + 2) True-rms |
AC bandwidth: |
20 kHz |
Maximum resolution: |
10 μV |
|
Current DC |
Maximum amps: |
10 A (20 A for 30 seconds maximum) |
Amps accuracy: |
± (0.2 % + 2) |
Maximum resolution: |
0.01 μA |
|
Current AC |
Maximum amps: |
10 A (20 A for 30 seconds maximum) |
Amps accuracy: |
± (1.0 % + 2) |
Maximum resolution: |
True-rms 0.01 μA |
|
Resistance |
Maximum resistance: |
50 MΩ |
Accuracy: |
± (0.2 % + 1) |
Maximum resolution: |
0.01 Ω |
|
Capacitance |
Maximum capacitance: |
9,999 μF |
Accuracy: |
± (1 % + 2) |
Maximum resolution: |
0.001 nF |
|
Frequency |
Maximum frequency: |
200 kHz |
Accuracy: |
± (0.005 % + 1) |
Maximum resolution: |
0.001 Hz |
|
Duty Cycle |
Maximum duty cycle: |
99.90 % |
Accuracy: |
± (0.2 % per khz +0.1 %) |
Maximum resolution: |
0.10 % |
|
Temperature |
Range: |
-200.0 °C to 1090 °C (-328 °F to 1994 °F) excluding probe |
|
80BK Temperature Probe |
Range: |
-40.0 °C to 260 °C (-40 °F to 500 °F) |
Accuracy: |
2.2 °C or 2 % whichever is greater |
|
Conductance |
Maximum conductance: |
60.00 nS |
Accuracy: |
± (1.0 % + 10) |
Maximum resolution: |
0.001 nS |
|
Diode |
Range: |
3 V |
Resolution: |
1 mV |
Accuracy: |
± (2 % + 1) |
|
Duty Cycle Range |
Accuracy: |
Within ± (0.2 % per kHz + 0.1 %) |
|
Measurements restriction in Ex-hazardous area |
Voltage: |
65 V |
Current: |
5 A |
|
Environmental Specifications |
Operating Temperature |
|
Storage Temperature |
|
Humidity (Without Condensation) |
|
0 % to 80 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 50 °C) |
|
Operating Altitude |
|
Safety Specifications |
Overvoltage category |
|
EN 61010-1 to 1000 V CAT III, 600 V CAT IV |
|
Agency Approvals |
|
ATEX certification |
|
Agency Approvals |
|
Mechanical & General Specifications |
Size |
|
201 x 98 x 52 mm (with holster) |
|
Weight |
|
12,5 oz. (355 kg) with holster |
|
Display (Digital) |
|
6000 counts updates 4/sec. 19,999 counts in high-resolution mod |
|
Display (Analog) |
|
32 segments, updates 40/sec. |
|
Warranty |
|
Battery Life |
|
~400 hours typical without backlight |
|
Shock |
|
1 Meter drop per IEC 61010-1:2001 |
|
Vibration |
|
Per MIL-PRF-28800 for a Class 2 instrument |
|
Intrinsically safe version of the world’s most popular Multimeter
With its high performance, accuracy and motor drive compatibility, the Fluke 87V is the most popular industrial multimeter in the world. Now Fluke has introduced a new intrinsically safe version – the 87V Ex – for measurements in and around hazardous areas.
The new Fluke 87V Ex has all the measurement and troubleshooting functions of the proven Fluke 87V. Unlike most other ATEX-certified tools, it can be used both inside and outside the hazardous zone (ATEX Zones 1 & 2) without compromising performance or compliance. So there’s no need to carry different tools for use inside or outside the hazardous zones. It also has a built-in thermometer with TC probe, further reducing technicians’ tool counts.
|